3XAM17-1-208-400

Circuit Breakers

CIRCUIT BREAKER

3XAM17-1-208-400

5925-00-103-3842

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac all locations

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    2.280 inches maximum

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    17.000 minimum at 200 pct all locations and 50.000 maximum at 200 pct all locations

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Unpackaged Unit Weight

    13.000 ounces

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Nominal Thread Size

    0.138 inches

  • Body Length

    2.520 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.200 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Inclosure Protection Type For Which Designed

    fungus resistant and explosion resistant

  • Terminal Type And Quantity

    6 screw

  • Mounting Surface To Terminal End Distance

    2.010 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...