25-4752-1031

Relays and Solenoids

RELAY,METER MOVEMENT

25-4752-1031

5945-00-731-8219

5945 - Relays and Solenoids

Lfe Instruments

RELAY,METER MOVEMENT

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Meter Depth To Mounting Flange

    1.455 inches nominal

  • Meter Body Diameter

    2.130 inches nominal

  • Mounting Flange Diameter

    2.796 inches nominal

  • Release Method

    deenergize lock-in coil

  • Lock In Device Type

    coil

  • Reset Facility Feature

    provided

  • Meter Mounting Type

    flush

  • Meter Movement Voltage In Volts

    0.150 nominal

  • Main Contact Current Rating

    450.0 microamperes nominal

  • Voltage Rating

    175.0 volts nominal

  • Terminal Type

    wire loop

  • Terminal Quantity

    3

  • Contact Closing Condition

    increase value

  • Meter Movement Current Range

    p0.0/p200.0 microamperes

  • Meter Movement Current Type

    dc

  • Main Contact Current Type

    dc

  • Main Contact Arrangement

    1 pole,single throw,both positions maintained

  • Mounting Configuration

    three no. 4-40 thd studs 120 deg apart on 1.220 in. radius

  • Case Material

    metal