172063-000
Coils and Transformers
TRANSFORMER,POWER
172063-000
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Rating
400.0 hertz nominal single component
-
Thread Class (Non-Core)
err-070
-
Nominal Thread Size
0.112 inches 2nd group
-
Mounting Facility Quantity
2 1st group
-
Terminal Type And Quantity
25 turret
-
Winding Operating Current
40.0 milliamperes ac nominal single component 3rd secondary
-
Winding Function And Quantity
2 primary single component and 6 secondary single component
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.000 inches nominal single mounting facility 4th center group
-
Nominal Thread Size
0.112 inches 3rd group
-
Nominal Thread Size
0.164 inches 4th group
-
Cubic Measure (Non-Core)
7.77 cubic inches
-
Mounting Facility Quantity
4 4th group
-
Winding Operating Current
424.2 milliamperes ac nominal single component 4th secondary
-
Input-Output Phase Relationship
single phase to single phase single component and single phase to three phase single component and three phase to three phase single component and three phase to single phase single component
-
Winding Operating Voltage
3.00 ac volts nominal single component 4th secondary
-
Winding Operating Voltage
1.29 ac kilovolts nominal single component 3rd secondary
-
Winding Power Rating
5.46 volts-amperes single component 2nd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.562 inches nominal single mounting facility 4th center group
-
Winding Power Rating
1.6 volts-amperes single component 1st secondary
-
Overall Height
0.875 inches nominal
-
Winding Power Rating
1.27 volts-amperes single component 4th secondary
-
Winding Operating Voltage
65.00 ac volts nominal single component 2nd secondary
-
Winding Operating Current
84.0 milliamperes ac nominal single component 2nd secondary
-
Winding Operating Voltage
5.66 ac volts nominal single component 2nd primary
-
Thread Series Designator
unc all groupings
-
Winding Power Rating
51.6 volts-amperes single component 3rd secondary
-
Winding Operating Voltage
40.00 ac volts nominal single component 1st secondary
-
Distance Between Mounting Facility Centers
1.125 inches nominal single mounting facility 1st center group
-
Mounting Facility Quantity
5 3rd group
-
Maximum Operating Temp
170.0 deg celsius
-
Overall Length
4.062 inches maximum
-
Winding Tap Location (Non-Core)
err-070
-
Transformer Winding Connection Type
wye-delta
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.687 inches nominal single mounting facility 3rd center group
-
Winding Operating Voltage
41.00 ac volts nominal single component 1st primary
-
Inclosure Type
fully inclosed
-
Mounting Method
threaded hole all groupings
-
Mounting Facility Quantity
3 2nd group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.125 inches nominal single mounting facility 3rd center group
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Special Features
2 primary windings; 6 secondary windings
-
Nominal Thread Size
0.138 inches 1st group
-
Overall Width
2.188 inches nominal
-
Winding Operating Current
40.0 milliamperes ac nominal single component 1st secondary
-
Reliability Indicator
not established