604GX5
Switches
SWITCH,PRESSURE
604GX5
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Stimulus Rating
50.00 differential point nominal pounds per square inch
-
Contact Load Current Rating
15.0 amperes resistive load second voltage and 15.0 amperes inductive load second voltage
-
Features Provided
electrical box connector
-
Thread Quantity Per Inch
18 single pressure connection
-
Media For Which Designed
gas or liquid
-
Contact Load Current Rating
1.0 amperes resistive load third voltage
-
Proof Pressure
4500.00 pounds per square inch
-
Contact Voltage Rating In Volts
125.0 ac at sea level second voltage
-
Terminal Type
solder stud
-
Longest Horizontal Distance Between Mounting Centers
4.250 inches nominal
-
Contact Voltage Rating In Volts
28.0 dc at sea level fourth voltage
-
Body Height
3.100 inches nominal
-
Pressure Switch Type
gage
-
Contact Adjustment Type
internal deactuation point screw and internal actuation point screw
-
Mounting Method
bracket
-
Nominal Thread Size
0.250 inches single pressure connection
-
Overall Height
6.230 inches nominal
-
Contact Load Current Rating
15.0 amperes resistive load first voltage and 15.0 amperes inductive load first voltage
-
Contact Voltage Rating In Volts
250.0 ac at sea level first voltage
-
Overall Length
4.250 inches nominal
-
Pressure Connector Type
gasket seal, threaded external single connection
-
Contact Voltage Rating In Volts
125.0 dc at sea level third voltage
-
Longest Vertical Distance Between Mounting Centers
3.100 inches nominal
-
Thread Series Designator
npt single pressure connection
-
Nonpile-Up Contact Arrangement
5 two circuit, double break/double make, both positions maintained
-
Contact Load Current Rating
6.0 amperes resistive load fourth voltage and 5.0 amperes inductive load fourth voltage
-
Contact Adjustability
deactuation point adjustable and actuation point adjustable
-
Contact Adjustment Range
+350.00/+675.00 actuation point pounds per square inch and +350.00/+625.00 deactuation point pounds per square inch
-
Mounting Facility Pattern
four position rectangular
-
Contact Action Stimulus
increase