MS27401-31

Relays and Solenoids

RELAY,ELECTROMAGNETIC

MS27401-31

5945-01-127-3807

5945 - Relays and Solenoids

Military Standards

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    2 unthreaded hole single mounting facility

  • Main Contact Load Current Rating At Maximum Rated Voltage

    4.0 amperes ac motor load and 4.0 amperes dc motor load

  • Overall Height

    1.010 inches maximum

  • Operating Voltage Rating And Type At Specified Temp

    42.0 volts teardrop, two holes type 4f single winding

  • Nonpile-Up Main Contact Arrangement

    2 pole, double throw, one position momentary

  • Test Data Document

    81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performance

  • Main Contact Load Current Rating At Maximum Rated Voltage

    10.0 amperes ac resistive load and 10.0 amperes dc resistive load

  • Features Provided

    coil voltage suppression and polarized

  • Mounting Facility Pattern

    in-line single mounting facility

  • Duty Type

    continuous

  • Unthreaded Mounting Hole Diameter

    0.157 inches minimum single mounting facility and 0.161 inches maximum single mounting facility

  • Time Delay

    10.00 seconds maximum fixed operate and release time

  • Coil Quantity

    1

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    1.406 inches nominal single mounting facility

  • Overall Width

    0.525 inches maximum

  • Specification/Standard Data

    96906-ms27401 government standard

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Terminal Type And Quantity

    8 wire hook all functions

  • Main Contact Load Current Rating At Maximum Rated Voltage

    2.0 amperes ac lamp load and 2.0 amperes dc lamp load

  • Overall Length

    1.718 inches maximum

  • Winding Quantity

    1

  • Environmental Protection

    hermetic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...