29-587240-1

Circuit Breakers

CIRCUIT BREAKER

29-587240-1

5925-01-184-6912

5925 - Circuit Breakers

General Dynamics C4 Systems Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 single location

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Thread Series Designator

    unc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 push button

  • Nominal Thread Size

    0.375 inches

  • Boss Height

    0.406 inches nominal

  • Body Style

    single pole type

  • Frequency In Hertz

    60.0 single location

  • Trip Release Ambient Temp Rating

    70.0 deg celsius nominal single location

  • Overall Length

    1.750 inches maximum

  • Unpackaged Unit Weight

    0.062 ounces

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Center To Center Distance Between Terminals Parallel To Length

    0.780 inches nominal

  • Switch Current Rating And Type In Amps

    1.0 ac

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.950 inches minimum and 1.970 inches maximum

  • Mounting Surface To Terminal End Distance

    2.250 inches maximum

  • Trip Release Method

    thermal-magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Terminal Type And Quantity

    2 tab, solder lug

  • Inclosure Protection Type For Which Designed

    waterproof and dustproof

  • Overall Width

    0.563 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...