MS27400-31U

Relays and Solenoids

RELAY,ELECTROMAGNETIC

MS27400-31U

5945-01-197-1953

5945 - Relays and Solenoids

Military Standards

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Main Contact Load Current Rating At Maximum Rated Voltage

    4.0 amperes ac motor load and 4.0 amperes dc motor load

  • Overall Height

    1.280 inches maximum

  • Storage Type

    general purpose warehouse

  • Criticality Code Justification

    feat

  • Time Delay

    0.015 seconds maximum fixed operate and release time

  • Cubic Measure

    2.254 cubic inches

  • Precious Material

    gold

  • Precious Material And Location

    terminal surfaces gold

  • Environmental Protection

    hermetic

  • Mounting Slot Width

    0.150 inches nominal single mounting facility

  • Arc Quenching Method

    air

  • Specification/Standard Data

    96906-ms27400 government standard

  • Test Data Document

    81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle

    1.396 inches minimum single mounting facility and 1.446 inches maximum single mounting facility

  • Case Material

    metal

  • Main Contact Load Current Rating At Maximum Rated Voltage

    2.0 amperes ac lamp load and 2.0 amperes dc lamp load

  • Mounting Facility Pattern

    triangle single mounting facility

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Nonpile-Up Main Contact Arrangement

    4 pole, double throw, one position momentary

  • Special Features

    failure rate level 0.5 percent

  • Overall Width

    1.025 inches maximum

  • Operating Voltage Rating And Type At Specified Temp

    28.0 volts dc 25 deg celsius single winding

  • Coil Quantity

    1

  • Terminal Type And Quantity

    14 pin all functions

  • Main Contact Load Current Rating At Maximum Rated Voltage

    8.0 amperes ac inductive load and 8.0 amperes dc inductive load

  • Duty Type

    continuous

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    0.625 inches nominal single mounting facility

  • Features Provided

    coil voltage suppression and polarized

  • Winding Quantity

    1

  • Overall Length

    1.718 inches maximum

  • Mounting Facility Type And Quantity

    3 slotted hole single mounting facility

  • Main Contact Load Current Rating At Maximum Rated Voltage

    10.0 amperes ac resistive load and 10.0 amperes dc resistive load

  • ~1

    data on certain environmental and performance

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...