KNP11A12-120

Relays and Solenoids

RELAY,ELECTROMAGNETIC

KNP11A12-120

5945-01-233-4251

5945 - Relays and Solenoids

Tyco Electronics Corporation

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Winding Quantity

    1

  • Thread Direction

    right-hand single mounting facility

  • Terminal Type And Quantity

    8 tab, solder lug all functions

  • Contact Surface Treatment

    cadmium plated

  • Operating Voltage Rating And Type At Specified Temp

    120.0 volts ac 25 deg celsius single winding

  • Main Contact Maximum Voltage Rating In Volts

    120.0 ac and 32.0 dc

  • Purpose For Which Designed

    general

  • Contact Material

    silver

  • Coil Quantity

    1

  • Time Delay

    0.006 seconds maximum fixed release time

  • Thread Series Designator

    unc single mounting facility

  • Thread Class

    2b single mounting facility

  • Mounting Facility Type And Quantity

    1 threaded hole single mounting facility

  • Duty Type

    continuous

  • Cubic Measure

    1.653 cubic inches

  • Case Material

    plastic

  • Environmental Protection

    dustproof

  • Main Contact Load Current Rating At Maximum Rated Voltage

    3.0 amperes ac resistive load and 3.0 amperes dc resistive load

  • Fragility Factor

    moderately rugged

  • Nominal Thread Size

    0.138 inches single mounting facility

  • Precious Material And Location

    contacts silver

  • Overall Width

    0.980 inches maximum

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Frequency In Hertz

    60.0 nominal

  • Nonpile-Up Main Contact Arrangement

    2 pole, double throw, one position momentary

  • Winding Dc Resistance Rating

    3.9 kilohms nominal single winding

  • Overall Length

    1.000 inches maximum

  • Time Delay

    0.013 seconds maximum fixed operate time

  • Overall Height

    1.687 inches maximum

  • Arc Quenching Method

    air

  • Thread Quantity Per Inch

    32 single mounting facility

  • Nominal Operating Current Rating And Type

    11.0 milliamperes ac single winding

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...