KDW2301-1
Coils and Transformers
TRANSFORMER,POWER
KDW2301-1
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Power Rating
220.0 volts-amperes single component 1st secondary
-
Reliability Indicator
not established
-
Winding Operating Voltage
33.70 ac volts nominal single component 2nd secondary
-
Thread Class (Non-Core)
err-070
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Frequency Rating
60.0 hertz nominal single component
-
Winding Operating Current
3.0 amperes ac nominal single component 2nd secondary
-
Maximum Transformer Power Rating
321.1 volt-ampere single component
-
Criticality Code Justification
zzzy
-
Winding Power Rating
101.1 volts-amperes single component 2nd secondary
-
Terminal Type And Quantity
1 terminal block w/screws
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.500 inches nominal single mounting facility 1st center group
-
Reference Number Differentiating Characteristics
reference number differentiating material will be in accordance with naval inventory control point activity hx quality control. manufacturing and testing specifications available at the dla icp
-
Mounting Facility Quantity
4 all groupings
-
Winding Operating Voltage
220.00 ac volts nominal single component 1st secondary
-
Thread Direction (Non-Core)
err-070
-
Body Height
5.220 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.312 inches nominal single mounting facility 2nd center group
-
Body Length
5.250 inches maximum
-
Thread Series Designator
unf all groupings
-
Body Width
3.600 inches maximum
-
Maximum Operating Temp
155.0 deg celsius
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Inclosure Type
fully inclosed
-
Nominal Thread Size
0.190 inches all groupings
-
Mounting Method
threaded hole all groupings
-
Winding Operating Current
1.0 amperes ac nominal single component 1st secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.500 inches nominal single mounting facility 2nd center group
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.562 inches nominal single mounting facility 1st center group
-
Special Features
item must comply with requirements of defense supply center columbus production standard no. lo3542