MIL-R-6106
Relays and Solenoids
RELAY,ELECTROMAGNETIC
MIL-R-6106
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
1.718 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.396 inches minimum and 1.446 inches maximum
-
Mounting Slot Width
0.150 inches nominal
-
Case Material
metal
-
End Item Source
53711
-
Purpose For Which Designed
general
-
Winding Dc Resistance Rating
320.0 ohms nominal
-
Duty Type
continuous
-
Arc Quenching Method
air
-
Mounting Facility Type And Quantity
2 slotted hole
-
Storage Type
general purpose warehouse
-
Features Provided
polarized
-
Cubic Measure
1.634 cubic inches
-
Mounting Facility Pattern
two position in-line
-
Nonpile-Up Main Contact Arrangement
2 pole,double throw,one position momentary
-
Nominal Operating Current Rating And Type
110.0 milliamperes dc
-
Time Delay
0.01 seconds maximum
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac and 10.0 amperes dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes ac and 8.0 amperes dc
-
Special Features
failure rate level 0.1 percent
-
Test Data Document
81349-mil-r-6106 specification
-
Terminal Type And Quantity
8 pin
-
Overall Height
1.290 inches maximum
-
Overall Width
0.525 inches maximum
-
Environmental Protection
hermetic
-
Fragility Factor
moderately rugged
-
Winding Quantity
1
-
Coil Quantity
1
-
End Item Name
panel,cont tu
-
Criticality Code Justification
feat
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac and 2.0 amperes dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac and 4.0 amperes dc
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Unpackaged Unit Weight
0.100 pounds
-
Specification/Standard Data
96906-ms27401 government standard