APL-111-1REC1-40-203-MA

Circuit Breakers

CIRCUIT BREAKER

APL-111-1REC1-40-203-MA

5925-01-264-8107

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    iso s

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.040 maximum at 200 pct all locations

  • Thread Pitch In Millimeters

    0.50

  • Nominal Thread Size

    3.0 millimeters

  • Actuator Position Designation

    at each pole

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Method

    magnetic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Iii Storage Type

    general purpose warehouse

  • Iii Arc Quenching Method

    magnetic blowout

  • Iii Fragility Factor

    moderately rugged

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Body Style

    8c multipole-multiple actuator type

  • Terminal Type And Quantity

    6 threaded stud

  • Iii Unpackaged Unit Weight

    11.100 ounces

  • Frequency In Hertz

    400.0 all locations

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Terminal Type

    quick disconnect, male

  • Internal Trip Release Configuration

    series trip all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    3 toggle

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Iii Special Handling Feature

    magnetic

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Pole Quantity

    3

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

  • Boss Height

    0.150 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Case Material

    plastic

  • Body Width

    2.250 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.