Technical Characteristics
-
Terminal Type And Quantity
2 tab w/screw
-
Thread Series Designator
unef
-
Switch Current Rating And Type In Amps
0.5 ac and
-
Inclosure Protection Type For Which Designed
vibration resistant
-
Inclosure Protection Type For Which Designed
hermetically sealed and
-
Switch Location And Position Designation
internal at pole one
-
Internal Trip Release Configuration
series trip single location
-
Reset Method
manual
-
Trip Release Method
magnetic single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location
-
Iii Storage Type
general purpose warehouse
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Iii Fragility Factor
moderately rugged
-
Switch Contact Arrangement
single pole, double throw
-
Case Material
metal
-
Body Width
0.625 inches maximum
-
Iii Unpackaged Unit Weight
1.800 ounces
-
Switch Voltage Rating And Type In Volts
50.0 dc
-
Switch Voltage Rating And Type In Volts
120.0 ac and
-
Switch Current Rating And Type In Amps
0.5 dc
-
Switch Terminal Type
pin
-
Inclosure Protection Type For Which Designed
shock resistant and
-
Nominal Thread Size
0.375 inches
-
Auxiliary Switch Function And Quantity
1 alarm
-
Actuator Position Designation
at pole one
-
Actuator Function
trip-reset
-
Manual Actuator Type And Quantity
1 toggle
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Trip Release Characteristic
instantaneous single location
-
Circuit Protection Type
overcurrent single location
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location
-
Thread Quantity Per Inch
32
-
Iii Special Handling Feature
magnetic
-
Iii Arc Quenching Method
magnetic blowout
-
Pole Quantity
1
-
Mounting Surface To Terminal End Distance
1.605 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Body Length
1.562 inches maximum
-
Bushing Length
0.380 inches maximum
-
Body Style
2a single pole type
-
Thread Pitch Diameters
0.3503 to 0.3537 inches