IUGN66-33968-5

Circuit Breakers

CIRCUIT BREAKER

IUGN66-33968-5

5925-01-567-9123

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations and 7500.0 dc all locations

  • Reset Method

    manual

  • End Item Identification

    boat,patrol,34 foot, 34pb0601 thru 34pb0609 and 34pb0701

  • Actuator Position Designation

    at pole one

  • Trip Release Characteristic

    time delay all locations

  • Body Length

    2.000 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Part Name Assigned By Controlling Agency

    cage: iug magnetic circuit protector

  • Unthreaded Mounting Hole Diameter

    0.156 inches nominal

  • Terminal Type And Quantity

    4 screw

  • Bushing Length

    0.240 inches nominal

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Special Features

    screw terminals are bent in 30 degrees; screws are 0.313 in. long and are no. 10-30 with captive washers

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 80.0 dc all locations

  • Mounting Surface To Terminal End Distance

    2.075 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    1000.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Body Width

    1.515 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations and 5.0 amperes dc all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...