NSN: 5915-01-163-2549

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

5915 - Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Voltage Drop Per Function

    1.2 volts ac 5th radio interference and 2.0 volts dc 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference

  • Overall Length

    2.012 inches nominal

  • Input Terminal Identification

    mil-c-38999

  • Unthreaded Mounting Hole Diameter

    0.126 inches minimum and 0.132 inches maximum

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Maximum Dielectric Withstanding Ac Rms Voltage

    300.0 volts at sea level

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Overall Width

    1.125 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Special Features

    twenty-two filtered functions; twenty-four unfiltered functions

  • Precious Material

    gold

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 5th radio interference 5th function and 200.0 volts dc 5th radio interference 5th function

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.906 inches nominal

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Full Load Insertion Loss Frequencies In Megahertz

    2.0 and 1.0 and 0.1 and 10.0 and 100.0 and 1000.0

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 2nd radio interference 2nd function and 200.0 volts dc 2nd radio interference 2nd function

  • Maximum Voltage Drop Per Function

    1.2 volts ac 2nd radio interference and 2.0 volts dc 2nd radio interference

  • Output Terminal Manufacturer Code

    71468

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Vibration Resistance Range In Hertz

    +10.0/+500.0

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Style Designator

    filter connector

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 1st radio interference 1st function and 200.0 volts dc 1st radio interference 1st function

  • Input Terminal Manufacturer Code

    71468

  • Maximum Voltage Drop Per Function

    1.2 volts ac 3rd radio interference and 2.0 volts dc 3rd radio interference

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Body Material

    aluminum

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 3rd radio interference 3rd function and 200.0 volts dc 3rd radio interference 3rd function

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 4th radio interference and 2.0 volts dc 4th radio interference

  • Features Provided

    moisture resistant and shock resistant

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Precious Material And Location

    contact surfaces gold

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Full Load Minimum Insertion Loss At Specified Frequency In Decibels

    10.0 and 16.0 and 40.0 and 2.0 and 75.0 and 90.0

  • Inclosure Type

    hermetically sealed

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 6th radio interference 6th function and 200.0 volts dc 6th radio interference 6th function

  • Functional Terminal Type And Quantity

    46 friction w/grounding strap and pin input-output

  • Output Terminal Identification

    mil-c-38999

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Body Surface Treatment

    cadmium

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 4th radio interference 4th function and 200.0 volts dc 4th radio interference 4th function

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    5.0 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Maximum Voltage Drop Per Function

    1.2 volts ac 1st radio interference and 2.0 volts dc 1st radio interference

  • Overall Height

    1.125 inches nominal

  • Maximum Dielectric Withstanding Dc Voltage

    300.0 volts at sea level

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.906 inches nominal

  • Maximum Temp Rise

    25.0 deg celsius

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 6th radio interference and 2.0 volts dc 6th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...