NSN: 5915-01-266-7852
Filters and Networks
FILTER,BAND PASS
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 2nd band pass and 30.0 minimum 2nd band pass and 3.0 maximum 2nd band pass and 30.0 minimum 2nd band pass
-
Load Impedance Per Function
50.0 ohms 2nd band pass
-
Specified Frequencies Of Discrimination Per Function
69.00 megahertz 1st band pass and 69.95 megahertz 1st band pass and 70.05 megahertz 1st band pass and 71.00 megahertz 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
6.0 6th band pass
-
Voltage Standing Wave Ratio Frequency Limits Per Function
69.73 hercules no.5599.1 three phase to two phase and 70.27 hercules no.5599.1 three phase to two phase
-
Insertion Loss At Reference Frequency Per Function In Decibels
6.0 5th band pass
-
Specified Frequencies Of Discrimination Per Function
69.78 megahertz 6th band pass and 65.00 megahertz 6th band pass and 70.22 megahertz 6th band pass and 75.00 megahertz 6th band pass
-
Frequency Band Width Per Function
69.82 megahertz 4th band pass and 70.18 megahertz 4th band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 4th band pass and 30.0 minimum 4th band pass and 3.0 maximum 4th band pass and 30.0 minimum 4th band pass
-
Reference Frequency Per Function
70.0 hercules no.5599.1 gigahertz
-
Overall Height
0.780 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd band pass
-
Inclosure Type
encased
-
Principal Circuitry Type Per Function
inductance-capacitance 6th band pass
-
Source Impedance Rating Per Function
50.0 ohms 4th band pass
-
Body Length
3.800 inches maximum
-
Voltage Standing Wave Ratio Frequency Limits Per Function
69.91 hercules no.5599.1 two phase to three phase and 70.09 hercules no.5599.1 two phase to three phase
-
Frequency Band Width Per Function
69.78 megahertz 6th band pass and 70.22 megahertz 6th band pass
-
Voltage Standing Wave Ratio Frequency Limits Per Function
69.82 hercules no.5599.1 hertz and 70.18 hercules no.5599.1 hertz
-
Load Impedance Per Function
50.0 ohms 1st band pass
-
Principal Circuitry Type Per Function
inductance-capacitance 4th band pass
-
Load Impedance Per Function
50.0 ohms 5th band pass
-
Mounting Facility Screw Thread Series Designator
unc
-
Insertion Loss At Reference Frequency Per Function In Decibels
6.0 1st band pass
-
Frequency Band Width Per Function
69.95 megahertz 1st band pass and 70.05 megahertz 1st band pass
-
Voltage Standing Wave Ratio Frequency Limits Per Function
69.95 hercules no.5599.1 pulses per second and 70.05 hercules no.5599.1 pulses per second
-
Operating Temp Range
-32.0/+70.0 deg celsius
-
Source Impedance Rating Per Function
50.0 ohms 2nd band pass
-
Functional Terminal Type And Quantity
6 pin input 1st function
-
Reference Frequency Per Function
70.0 hercules no.5599.1 two phase to two phase
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum 1st band pass and 3.0 maximum 1st band pass and 3.0 maximum 1st band pass and 30.0 minimum 1st band pass
-
Specified Frequencies Of Discrimination Per Function
68.20 megahertz 3rd band pass and 70.09 megahertz 3rd band pass and 69.91 megahertz 3rd band pass and 71.80 megahertz 3rd band pass
-
Frequency Band Width Per Function
69.91 megahertz 2nd band pass and 70.09 megahertz 2nd band pass
-
Voltage Standing Wave Ratio Per Function
2.0 5th band pass
-
Reference Frequency Per Function
70.0 hercules no.5599.1 pulses per second
-
Load Impedance Per Function
50.0 ohms 3rd band pass
-
Source Impedance Rating Per Function
50.0 ohms 1st band pass
-
Voltage Standing Wave Ratio Per Function
2.0 4th band pass
-
Reference Frequency Per Function
70.0 hercules no.5599.1 hertz
-
Voltage Standing Wave Ratio Per Function
2.0 3rd band pass
-
Specified Frequencies Of Discrimination Per Function
69.73 megahertz 5th band pass and 64.70 megahertz 5th band pass and 70.27 megahertz 5th band pass and 75.30 megahertz 5th band pass
-
Source Impedance Rating Per Function
50.0 ohms 5th band pass
-
Vibration Resistance Range In Hertz
+10.0/+200.0
-
Voltage Standing Wave Ratio Per Function
2.0 2nd band pass
-
Functional Terminal Type And Quantity
4 pin ground 3rd function
-
Specified Frequencies Of Discrimination Per Function
68.20 megahertz 2nd band pass and 70.09 megahertz 2nd band pass and 69.91 megahertz 2nd band pass and 71.80 megahertz 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
6.0 4th band pass
-
Functional Terminal Type And Quantity
6 pin output 2nd function
-
Body Height
0.550 inches maximum
-
Mounting Facility Type And Quantity
4 threaded stud
-
Specified Frequencies Of Discrimination Per Function
66.50 megahertz 4th band pass and 70.18 megahertz 4th band pass and 69.82 megahertz 4th band pass and 73.50 megahertz 4th band pass
-
Principal Circuitry Type Per Function
inductance-capacitance 5th band pass
-
Nominal Thread Size
0.086 inches
-
Insertion Loss At Reference Frequency Per Function In Decibels
6.0 3rd band pass
-
Load Impedance Per Function
50.0 ohms 6th band pass
-
Body Width
3.250 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 3rd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum 6th band pass and 3.0 maximum 6th band pass and 3.0 maximum 6th band pass and 30.0 minimum 6th band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
6.0 2nd band pass
-
Principal Circuitry Type Per Function
inductance-capacitance 1st band pass
-
Load Impedance Per Function
50.0 ohms 4th band pass
-
Frequency Band Width Per Function
69.91 megahertz 3rd band pass and 70.09 megahertz 3rd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 3rd band pass and 3.0 maximum 3rd band pass and 30.0 minimum 3rd band pass and 30.0 minimum 3rd band pass
-
Voltage Standing Wave Ratio Frequency Limits Per Function
69.78 hercules no.5599.1 gigahertz and 70.22 hercules no.5599.1 gigahertz
-
Reference Frequency Per Function
70.0 hercules no.5599.1 two phase to three phase
-
Special Features
5 unfiltered pin terminals
-
End Item Identification
modem,communications md-1208/g
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd band pass
-
Source Impedance Rating Per Function
50.0 ohms 6th band pass
-
Frequency Band Width Per Function
69.73 megahertz 5th band pass and 70.27 megahertz 5th band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Voltage Standing Wave Ratio Frequency Limits Per Function
69.91 hercules no.5599.1 two phase to two phase and 70.09 hercules no.5599.1 two phase to two phase
-
Reference Frequency Per Function
70.0 hercules no.5599.1 three phase to two phase
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 5th band pass and 30.0 minimum 5th band pass and 3.0 maximum 5th band pass and 30.0 minimum 5th band pass
-
Body Material
metal
-
Voltage Standing Wave Ratio Per Function
2.0 6th band pass
-
Voltage Standing Wave Ratio Per Function
2.0 1st band pass