Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Switch Location And Position Designation

    internal at pole two

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Switch Current Rating And Type In Amps

    10.0 ac and 1.0 dc

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Width

    0.719 inches minimum and 0.781 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Mounting Surface To Terminal End Distance

    2.000 inches minimum and 2.031 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.160 minimum at 200 pct all locations and 1.600 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Pole Quantity

    3

  • Nominal Thread Size

    0.138 inches

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Frequency In Hertz

    60.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    1.529 inches minimum and 1.591 inches maximum

  • Boss Height

    0.099 inches minimum and 0.161 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Body Length

    1.969 inches minimum and 2.031 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Manual Actuator Type And Quantity

    3 toggle

  • Specification/Standard Data

    81349-mil-c-55629/6 government specification

  • Features Provided

    high inrush protection

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.629 inches minimum and 1.691 inches maximum

  • Case Material

    plastic

  • Body Width

    2.219 inches minimum and 2.281 inches maximum

  • Terminal Type And Quantity

    6 threaded stud

  • ~1

    data on certain environmental and performanc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...