Technical Characteristics
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.925 inches minimum and 1.955 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Fragility Factor
moderately rugged
-
Boss Height
0.135 inches minimum and 0.165 inches maximum
-
Mounting Facility Type And Quantity
4 threaded hole
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac first location
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes dc second location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
at pole two
-
Internal Trip Release Configuration
series trip first location
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct first location
-
~1
ant
-
Inclosure Protection Type For Which Designed
moisture resistant and salt spray proof and shock resistant and vibration resist
-
Special Features
relay coil at pole two is instantaneous trip
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.700 minimum at 200 pct and 10.000 maximum at 200 pct second location
-
Frequency In Hertz
50.0 or 60.0
-
Unpackaged Unit Weight
3.700 ounces
-
Thread Series Designator
unc
-
Terminal Type And Quantity
6 threaded stud
-
Trip Release Duty Cycle
continuous second location
-
Internal Trip Release Configuration
series/relay trip second location
-
Actuator Function
trip-reset
-
Reset Method
manual
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
24.0 dc nominal second location
-
Trip Release Method
magnetic all locations
-
Circuit Protection Type
overcurrent all locations
-
Thread Quantity Per Inch
32
-
Storage Type
general purpose warehouse
-
Arc Quenching Method
magnetic blowout
-
Pole Quantity
2
-
Mounting Surface To Terminal End Distance
2.647 inches minimum and 2.677 inches maximum
-
Body Width
1.485 inches minimum and 1.515 inches maximum
-
Body Length
2.480 inches minimum and 2.500 inches maximum
-
Body Style
8c multipole-multiple actuator type