NSN: 5925-01-297-8574

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location and 3.0 amperes dc single location

  • Mounting Surface To Terminal End Distance

    1.525 inches minimum and 1.585 inches maximum

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Bushing Length

    0.458 inches minimum and 0.478 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct single location and 15.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    dustproof

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Actuator Position Designation

    at pole one

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    1.095 inches minimum and 1.155 inches maximum

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Terminal Type And Quantity

    2 tab, solder lug

  • Body Style

    single pole type

  • Body Length

    1.365 inches minimum and 1.385 inches maximum

  • Thread Series Designator

    un

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 50.0 dc single location

  • Case Material

    plastic

  • Body Width

    0.670 inches minimum and 0.690 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...