Technical Characteristics
-
Mounting Facility Type And Quantity
6 clip
-
Storage Type
general purpose warehouse
-
Special Handling Feature
magnetic
-
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac first location
-
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac third location
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac second location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic all locations
-
Body Style
11b multipole-single actuator type
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.250 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.260 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0
-
Main Contact Tripping Mechanism Type
trip free
-
Internal Trip Release Configuration
series trip first location
-
Internal Trip Release Configuration
series trip second location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.050 maximum at 200 pct first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct and 1.700 maximum at 200 pct second location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct and 1.700 maximum at 200 pct third location
-
Frequency In Hertz
50.0 or 60.0
-
Unpackaged Unit Weight
3.900 ounces
-
Terminal Type And Quantity
6 quick disconnect, male
-
Body Length
2.000 inches nominal
-
Body Height
1.770 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.250 inches minimum and 2.170 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.625 inches nominal
-
Fragility Factor
moderately rugged
-
Boss Height
0.125 inches nominal
-
Pole Quantity
3
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac second location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac all locations
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole two
-
Internal Trip Release Configuration
shunt trip third location
-
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
-
Special Features
neon illuminated handle