NSN: 5925-01-567-5134

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Method

    magnetic single location

  • Features Provided

    neutral pole, switchable

  • Terminal Type And Quantity

    2 wire hook

  • Special Features

    auxiliary switch rating: 0.5 amp at 120 vac or 50 vdc

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    40000.0 dc single location

  • Internal Trip Release Configuration

    series trip w/auxiliary load terminal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Body Length

    1.562 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location and 240.0 ac single location

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    800.0 single location

  • Thread Series Designator

    unef

  • Maximum Continuous Load Current Rating Per Pole

    10000.0 amperes dc single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 135 pct single location and 60.000 maximum at 135 pct single location

  • Bushing Length

    0.380 inches maximum

  • End Item Identification

    an/bqq-10(v) unit 4190 ti06 ph3, hf operator

  • Nominal Thread Size

    0.375 inches

  • Circuit Protection Type

    overcurrent single location

  • Part Name Assigned By Controlling Agency

    cage: ap/up magnetic circuit protector

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Pole Quantity

    1

  • Case Material

    metal

  • Body Width

    0.656 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Characteristic

    time delay single location

  • Supplementary Features

    fully sealed; waterproof panel integrity provided by o-ring bushing seal and silicon rubber gland within bushing/handle assy

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...