10158805-4
Circuit Breakers
CIRCUIT BREAKER
10158805-4
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
2 tab, solder lug
-
Switch Voltage Rating And Type In Volts
28.0 dc
-
Switch Current Rating And Type In Amps
7.0 dc
-
Body Style
single pole type
-
Switch Contact Arrangement
single pole, single throw, normally open
-
Trip Release Method
magnetic-hydraulic single location
-
Mounting Surface To Terminal End Distance
1.623 inches minimum and 1.653 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.700 minimum at 200 pct single location and 4.500 maximum at 200 pct single location
-
Bushing Length
0.280 inches minimum and 0.300 inches maximum
-
Nominal Thread Size
0.469 inches
-
Ultimate Trip Time Per Pole In Seconds
12.000 maximum single location
-
Switch Location And Position Designation
internal at pole one
-
Center To Center Distance Between Terminals Parallel To Length
1.225 inches minimum and 1.255 inches maximum
-
Auxiliary Switch Function And Quantity
1 control
-
Thread Series Designator
uns
-
Fragility Factor
moderately rugged
-
Reset Method
manual
-
Switch Terminal Type
turret
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Unthreaded Mounting Hole Diameter
0.110 inches minimum and 0.140 inches maximum
-
Manual Actuator Type And Quantity
1 push-pull
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location
-
Pole Quantity
1
-
Body Width
0.615 inches minimum and 0.635 inches maximum
-
Case Material
metal
-
Body Length
1.735 inches minimum and 1.765 inches maximum
-
Internal Trip Release Configuration
series trip single location
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes dc single location
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 dc single location