B3424
Switches
SWITCH,THERMOSTATIC
B3424
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Temp Sensing Element Type
capillary tube-bulb
-
Style Designator
cylindrical
-
Contact Load Current Rating
4.0 amperes resistive load second voltage
-
Contact Voltage Rating In Volts
30.0 dc at sea level second voltage
-
Contact Voltage Rating In Volts
250.0 ac at sea level first voltage
-
Contact Adjustment Type
external actuation point pointer
-
Bulb Diameter
0.320 inches nominal
-
Contact Adjustment Range
+100.00/+250.00 actuation point degrees fahrenheit
-
Bulb Length
1.500 inches nominal
-
Media For Which Designed
gas or liquid
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Capillary Tube Length
96.0 inches nominal
-
Overall Height
1.812 inches nominal
-
Mounting Facility Pattern
three position circular
-
Overall Diameter
3.125 inches nominal
-
Contact Stimulus Rating
235.00 actuation point nominal degrees fahrenheit and 99.00 deactuation point nominal degrees fahrenheit
-
Contact Adjustability
deactuation point not adjustable and actuation point adjustable, preset
-
Terminal Type
wire lead
-
Contact Load Current Rating
5.0 amperes resistive load first voltage
-
Mounting Method
base
-
Contact Action Stimulus
increase