6752-304-10
Circuit Breakers
CIRCUIT BREAKER
6752-304-10
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Internal Trip Release Configuration
series trip all locations
-
Storage Type
general purpose warehouse
-
Body Width
2.250 inches maximum
-
Test Data Document
81205-bacc182l10a drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Fragility Factor
moderately rugged
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Reset Method
manual
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Precious Material
silver
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations
-
Thread Quantity Per Inch
32
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.751 inches maximum
-
Manual Actuator Type And Quantity
1 push-pull
-
Actuator Position Designation
at pole two
-
Mounting Facility Type And Quantity
6 threaded hole
-
Body Style
multipole-single actuator type
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Nominal Thread Size
0.138 inches
-
Main Contact Tripping Mechanism Type
trip free
-
Body Length
2.200 inches maximum
-
Terminal Type And Quantity
6 screw
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
-
Inclosure Protection Type For Which Designed
general purpose
-
Body Height
2.125 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.780 inches minimum and 1.840 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Precious Material And Location
terminal surfaces silver
-
Unpackaged Unit Weight
0.500 pounds
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.751 inches maximum
-
Bushing Length
0.220 inches minimum and 0.280 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.471 inches minimum and 1.501 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac all locations
-
Case Material
plastic
-
Trip Release Method
thermal all locations