1163S10A250VAC125DC60C3

Circuit Breakers

CIRCUIT BREAKER

1163S10A250VAC125DC60C3

5925-00-003-8223

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    1.490 inches minimum and 1.510 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    4.349 inches minimum and 4.369 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.208 inches minimum and 0.228 inches maximum

  • Mounting Facility Type And Quantity

    4 threaded hole and 4 unthreaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Body Style

    9a single pole type

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 compression

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.164 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.350 minimum at 200 pct and 1.000 maximum at 200 pct single location

  • Frequency In Hertz

    60.0

  • Body Length

    5.240 inches minimum and 5.260 inches maximum

  • Body Height

    2.678 inches minimum and 2.698 inches maximum

  • Case Material

    plastic

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.349 inches minimum and 4.369 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.974 inches minimum and 0.994 inches maximum

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...