2XAM1516HKMG3-30-208-2-60
Circuit Breakers
CIRCUIT BREAKER
2XAM1516HKMG3-30-208-2-60
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Length
3.063 inches nominal
-
Switch Contact Arrangement
single pole, double throw
-
Trip Delay Time In Seconds Per Rated Continuous Current
5.000 minimum at 200 pct all locations and 18.000 maximum at 200 pct all locations
-
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Nominal Thread Size
0.138 inches
-
Boss Height
0.156 inches nominal
-
Frequency In Hertz
60.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
-
Manual Actuator Type And Quantity
2 toggle
-
Auxiliary Switch Function And Quantity
1 alarm
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Center To Center Distance Between Terminals Parallel To Width
1.031 inches nominal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Mounting Facility Type And Quantity
4 threaded hole
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Width
2.031 inches nominal
-
Body Style
multipole-multiple actuator type
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
-
Terminal Type And Quantity
4 threaded stud
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.031 inches nominal
-
External Actuator Linkage Arrangement
one and two linked
-
Switch Location And Position Designation
internal at pole one
-
Case Material
plastic
-
Mounting Surface To Terminal End Distance
3.429 inches nominal
-
Switch Terminal Type
tab, solder lug
-
Unpackaged Unit Weight
1.200 pounds
-
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac all locations
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Body Length
3.719 inches nominal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations