260-3072-000

Circuit Breakers

CIRCUIT BREAKER

260-3072-000

5925-00-004-6417

5925 - Circuit Breakers

Rockwell Collins Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    7a single pole type

  • Body Length

    2.189 inches maximum

  • Body Width

    0.750 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.438 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.181 inches nominal

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    6000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Ambient Temp Rating

    -55.0 deg celsius minimum single location and 125.0 deg celsius maximum

  • Bushing Length

    0.250 inches nominal

  • Mounting Surface To Terminal End Distance

    2.250 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    30.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Ultimate Trip Time Per Pole In Seconds

    3600.000 maximum single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 minimum at 200 pct single location and 60.000 maximum at 200 pct and 2.000 minimum at 400 pct and 7.000 maximum at 400 pct

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...