Technical Characteristics
-
Output Impedance Per Function W/Source Across Input
50.0 ohms 4th band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.177 inches minimum and 3.197 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 1st band pass
-
Source Impedance Rating Per Function
50.0 ohms 2nd band pass
-
Source Impedance Rating Per Function
50.0 ohms 3rd band pass
-
Input Impedance Per Function W/Load
50.0 ohms 1st band pass
-
Input Impedance Per Function W/Load
50.0 ohms 2nd band pass
-
Input Impedance Per Function W/Load
50.0 ohms 3rd band pass
-
Input Impedance Per Function W/Load
50.0 ohms 4th band pass
-
Output Impedance Per Function W/Source Across Input
50.0 ohms 1st band pass
-
Output Impedance Per Function W/Source Across Input
50.0 ohms 3rd band pass
-
Voltage Standing Wave Ratio Per Function
2.0 1st band pass
-
Voltage Standing Wave Ratio Per Function
2.0 single band pass
-
Mounting Facility Screw Thread Series Designator
unc
-
Insertion Loss At Reference Frequency Per Function In Decibels
4.5 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
4.5 4th band pass
-
Functional Terminal Type And Quantity
1 connector,receptacle input
-
Functional Terminal Type And Quantity
3 connector,receptacle output
-
Nominal Thread Size
0.138 inches
-
Load Impedance Per Function
50.0 ohms 1st band pass
-
Load Impedance Per Function
50.0 ohms 2nd band pass
-
Load Impedance Per Function
50.0 ohms 3rd band pass
-
Load Impedance Per Function
50.00 ohms 4th band pass
-
Output Impedance Per Function W/Source Across Input
50.0 ohms 2nd band pass
-
Voltage Standing Wave Ratio Per Function
2.0 2nd band pass
-
Voltage Standing Wave Ratio Per Function
2.0 3rd band pass
-
Inclosure Type
encased
-
Mounting Facility Type And Quantity
4 threaded stud
-
Insertion Loss At Reference Frequency Per Function In Decibels
4.5 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
4.5 3rd band pass
-
Frequency Band Width Per Function
160.00 megahertz 4th band pass and 260.00 megahertz 4th band pass
-
Frequency Band Width Per Function
60.00 megahertz 1st band pass and 260.00 megahertz 1st band pass
-
Frequency Band Width Per Function
60.00 megahertz 2nd band pass and 90.00 megahertz 2nd band pass
-
Frequency Band Width Per Function
90.00 megahertz 3rd band pass and 160.00 megahertz 3rd band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
6.677 inches minimum and 6.697 inches maximum
-
Operating Temp Range
m55.0/p71.0 deg celsius
-
Body Length
7.000 inches nominal
-
Body Width
1.250 inches nominal
-
Body Height
3.500 inches nominal
-
Reference Frequency Per Function
125.0 megahertz 3rd band pass
-
Reference Frequency Per Function
160.0 megahertz 1st band pass
-
Reference Frequency Per Function
210.0 megahertz 4th band pass
-
Reference Frequency Per Function
75.0 megahertz 2nd band pass
-
Source Impedance Rating Per Function
50.0 ohms 4th band pass