Technical Characteristics
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 60000.0 dc single location
-
Bushing Length
0.250 inches maximum
-
Trip Release Ambient Temp Rating
200.0 deg fahrenheit maximum single location
-
Nominal Thread Size
0.469 inches
-
Case Material
plastic
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Body Width
0.750 inches nominal
-
Actuator Function
trip-reset
-
Terminal Type And Quantity
2 screw
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.400 minimum at 200 pct single location and 2.000 maximum at 200 pct single location
-
Body Length
1.137 inches nominal
-
Thread Quantity Per Inch
32
-
Center To Center Distance Between Terminals Parallel To Length
0.650 inches nominal
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Manual Actuator Type And Quantity
1 push-pull
-
Mounting Surface To Terminal End Distance
1.812 inches nominal
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Ultimate Trip Time Per Pole In Seconds
5.000 nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac single location and 1.0 amperes dc single location
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc single location