6752-25-15-35

Circuit Breakers

CIRCUIT BREAKER

6752-25-15-35

5925-00-005-1922

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal

  • Unpackaged Unit Weight

    0.200 pounds

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Length

    2.189 inches maximum

  • Body Width

    0.750 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.160 inches minimum and 1.220 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.340 inches minimum and 2.400 inches maximum

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac and 15.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac and 30.0 dc

  • Trip Release Method

    thermal

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct and 45.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and explosion proof and corrosion resistant and dustproof and sand resistant

  • Frequency In Hertz

    400.0

  • Bushing Length

    0.469 inches minimum and 0.499 inches maximum

  • Case Material

    plastic

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    6000.0 ac and 6000.0 dc

  • Circuit Protection Type

    overcurrent

  • Internal Trip Release Configuration

    series trip

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...