2606D97G28

Circuit Breakers

CIRCUIT BREAKER

2606D97G28

5925-00-005-3115

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    4.125 inches nominal

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.500 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Trip Release Method

    magnetic all locations

  • Actuator Position Designation

    at pole two

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +450.0/+825.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    5.062 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    200.000 maximum at 200 pct all locations

  • Body Height

    3.375 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Case Material

    plastic

  • Unthreaded Mounting Hole Diameter

    0.187 inches nominal

  • Body Length

    6.000 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac all locations

  • Boss Height

    0.125 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 compression

  • Frequency In Hertz

    60.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Style

    multipole-single actuator type

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...