B483AJ47
Filters and Networks
FILTER,BAND PASS
B483AJ47
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Type
encased
-
Functional Terminal Type And Quantity
1 pin input 1st function
-
Mounting Facility Type And Quantity
7 terminal
-
Overall Length
1.510 inches maximum
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum 1st band pass and 1.5 maximum 1st band pass and 1.5 maximum 1st band pass and 30.0 minimum 1st band pass
-
Specified Frequencies Of Discrimination Per Function
489.25 kilohertz 1st band pass and 488.475 kilohertz 1st band pass and 489.30 kilohertz 1st band pass and 490.075 kilohertz 1st band pass
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Principal Circuitry Type Per Function
crystal 1st band pass
-
Source Impedance Rating Per Function
50.0 ohms 1st band pass
-
Principal Circuitry Type Per Function
crystal 2nd band pass
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Functional Terminal Type And Quantity
4 pin output 2nd function
-
Discrimination At Specified Frequencies Per Function In Decibels
1.5 maximum 2nd band pass and 1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass and 30.0 minimum 2nd band pass
-
Frequency Band Width Per Function
489.25 kilohertz 1st band pass and 489.30 kilohertz 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Frequency Band Width Per Function
489.55 kilohertz 2nd band pass and 489.60 kilohertz 2nd band pass
-
Load Impedance Per Function
50.0 ohms 2nd band pass
-
Functional Terminal Type And Quantity
2 pin ground 3rd function
-
Reference Frequency Per Function
489.575 single radio interference two phase to two phase
-
Body Width
1.120 inches maximum
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Load Impedance Per Function
50.0 ohms 1st band pass
-
Reference Frequency Per Function
489.275 single radio interference pulses per second
-
Specified Frequencies Of Discrimination Per Function
489.55 kilohertz 2nd band pass and 488.775 kilohertz 2nd band pass and 489.60 kilohertz 2nd band pass and 490.375 kilohertz 2nd band pass
-
Overall Height
0.595 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 2nd band pass
-
Operating Temp Range
-20.0/+71.0 deg celsius
-
Body Length
1.510 inches maximum