B483AJ40
Filters and Networks
FILTER,BAND PASS
B483AJ40
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Temp Range
-20.0/+71.0 deg celsius
-
Reference Frequency Per Function
487.325 single radio interference two phase to two phase
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.250 inches nominal
-
Frequency Band Width Per Function
487.00 kilohertz 1st band pass and 487.05 kilohertz 1st band pass
-
Overall Height
0.695 inches nominal
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Specified Frequencies Of Discrimination Per Function
487.35 kilohertz 2nd band pass and 486.525 kilohertz 2nd band pass and 487.30 kilohertz 2nd band pass and 488.125 kilohertz 2nd band pass
-
Frequency Band Width Per Function
487.30 kilohertz 2nd band pass and 487.35 kilohertz 2nd band pass
-
Body Width
1.120 inches maximum
-
Functional Terminal Type And Quantity
2 pin ground 3rd function
-
Source Impedance Rating Per Function
100.0 ohms 1st band pass
-
Load Impedance Per Function
100.0 ohms 1st band pass
-
Unpackaged Unit Weight
37.000 grams
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Source Impedance Rating Per Function
100.0 ohms 2nd band pass
-
Load Impedance Per Function
100.0 ohms 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass and 1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass
-
Inclosure Type
encased
-
Functional Terminal Type And Quantity
1 pin input 1st function
-
Mounting Facility Type And Quantity
7 terminal
-
Body Height
0.595 inches maximum
-
Body Surface Treatment
tin
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Discrimination At Specified Frequencies Per Function In Decibels
1.5 maximum 1st band pass and 1.5 maximum 1st band pass and 30.0 minimum 1st band pass and 30.0 minimum 1st band pass
-
Body Material
metal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.800 inches nominal
-
Style Designator
rectangular terminal/terminals on one surface
-
Specified Frequencies Of Discrimination Per Function
487.05 kilohertz 1st band pass and 487.00 kilohertz 1st band pass and 486.225 kilohertz 1st band pass and 487.825 kilohertz 1st band pass
-
Reference Frequency Per Function
487.025 single radio interference pulses per second
-
Functional Terminal Type And Quantity
4 pin output 2nd function
-
Body Length
1.510 inches maximum