F13212-54
Filters and Networks
FILTER,BAND PASS
F13212-54
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Source Impedance Rating Per Function
100.0 ohms 2nd band pass
-
Load Impedance Per Function
100.0 ohms 2nd band pass
-
Reference Frequency Per Function
491.225 single radio interference pulses per second
-
Inclosure Type
encased
-
Functional Terminal Type And Quantity
1 pin input 1st function
-
Reference Frequency Per Function
491.525 single radio interference two phase to two phase
-
Mounting Facility Type And Quantity
7 terminal
-
Body Height
0.595 inches maximum
-
Body Surface Treatment
tin
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Discrimination At Specified Frequencies Per Function In Decibels
1.5 maximum 1st band pass and 1.5 maximum 1st band pass and 30.0 minimum 1st band pass and 30.0 minimum 1st band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Frequency Band Width Per Function
491.50 kilohertz 2nd band pass and 491.55 kilohertz 2nd band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.800 inches nominal
-
Body Material
metal
-
Frequency Band Width Per Function
491.20 kilohertz 1st band pass and 491.25 kilohertz 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Unpackaged Unit Weight
37.000 grams
-
Specified Frequencies Of Discrimination Per Function
491.50 kilohertz 2nd band pass and 490.725 kilohertz 2nd band pass and 491.55 kilohertz 2nd band pass and 492.325 kilohertz 2nd band pass
-
Load Impedance Per Function
100.0 ohms 1st band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
1.5 maximum 2nd band pass and 1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass and 30.0 minimum 2nd band pass
-
Source Impedance Rating Per Function
100.0 ohms 1st band pass
-
Functional Terminal Type And Quantity
2 pin ground 3rd function
-
Body Width
1.120 inches maximum
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Overall Height
0.695 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.250 inches nominal
-
Operating Temp Range
-20.0/+71.0 deg celsius
-
Body Length
1.510 inches maximum
-
Functional Terminal Type And Quantity
4 pin output 2nd function
-
Specified Frequencies Of Discrimination Per Function
491.25 kilohertz 1st band pass and 490.425 kilohertz 1st band pass and 491.20 kilohertz 1st band pass and 492.025 kilohertz 1st band pass