6580A58

Filters and Networks

FILTER,BAND PASS

6580A58

5915-00-005-8821

5915 - Filters and Networks

Damon Corp Electronics Div

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Type

    encased

  • Functional Terminal Type And Quantity

    1 pin input 1st function

  • Body Height

    0.595 inches maximum

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Specified Frequencies Of Discrimination Per Function

    491.625 kilohertz 1st band pass and 492.45 kilohertz 1st band pass and 492.40 kilohertz 1st band pass and 493.225 kilohertz 1st band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.5 maximum 1st band pass and 1.5 maximum 1st band pass and 30.0 minimum 1st band pass and 30.0 minimum 1st band pass

  • Body Material

    metal

  • Frequency Band Width Per Function

    492.70 kilohertz 2nd band pass and 492.75 kilohertz 2nd band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Functional Terminal Type And Quantity

    4 pin output 2nd function

  • Body Length

    1.510 inches maximum

  • Source Impedance Rating Per Function

    50.0 ohms blank

  • Operating Temp Range

    -20.0/+71.0 deg celsius

  • Overall Height

    0.695 inches nominal

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.5 maximum 2nd band pass and 1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass and 30.0 minimum 2nd band pass

  • Reference Frequency Per Function

    492.725 single radio interference two phase to two phase

  • Mounting Facility Type And Quantity

    9 terminal

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

  • Load Impedance Per Function

    50.0 ohms blank

  • Frequency Band Width Per Function

    492.40 kilohertz 1st band pass and 492.45 kilohertz 1st band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.251 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.844 inches nominal

  • Reference Frequency Per Function

    492.425 single radio interference pulses per second

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Body Width

    1.120 inches maximum

  • Functional Terminal Type And Quantity

    2 pin ground 3rd function

  • Specified Frequencies Of Discrimination Per Function

    492.70 kilohertz 2nd band pass and 491.925 kilohertz 2nd band pass and 492.75 kilohertz 2nd band pass and 493.525 kilohertz 2nd band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...