B483AJ6
Filters and Networks
FILTER,BAND PASS
B483AJ6
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Band Width Per Function
477.10 kilohertz 2nd band pass and 477.15 kilohertz 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass and 1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass
-
Inclosure Type
encased
-
Specified Frequencies Of Discrimination Per Function
476.325 kilohertz 2nd band pass and 477.10 kilohertz 2nd band pass and 477.15 kilohertz 2nd band pass and 477.925 kilohertz 2nd band pass
-
Functional Terminal Type And Quantity
1 pin input 1st function
-
Mounting Facility Type And Quantity
7 terminal
-
Body Height
0.595 inches maximum
-
Body Surface Treatment
tin
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Operating Temp Range
-20.0/+71.0 deg celsius
-
Body Length
1.510 inches maximum
-
Functional Terminal Type And Quantity
4 pin output 2nd function
-
Style Designator
rectangular terminal/terminals on one surface
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.800 inches nominal
-
Body Material
metal
-
Discrimination At Specified Frequencies Per Function In Decibels
1.5 maximum 1st band pass and 1.5 maximum 1st band pass and 30.0 minimum 1st band pass and 30.0 minimum 1st band pass
-
Load Impedance Per Function
100.0 ohms 2nd band pass
-
Source Impedance Rating Per Function
100.0 ohms 2nd band pass
-
Specified Frequencies Of Discrimination Per Function
476.80 kilohertz 1st band pass and 476.025 kilohertz 1st band pass and 476.85 kilohertz 1st band pass and 477.625 kilohertz 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Reference Frequency Per Function
477.125 single radio interference two phase to two phase
-
Load Impedance Per Function
100.0 ohms 1st band pass
-
Frequency Band Width Per Function
476.80 kilohertz 1st band pass and 476.85 kilohertz 1st band pass
-
Source Impedance Rating Per Function
100.0 ohms 1st band pass
-
Functional Terminal Type And Quantity
2 pin ground 3rd function
-
Body Width
1.120 inches maximum
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Reference Frequency Per Function
476.825 single radio interference pulses per second
-
Unpackaged Unit Weight
42.000 grams
-
Overall Height
0.695 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.250 inches nominal