40-12290
Coils and Transformers
TRANSFORMER,POWER
40-12290
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
5.000 inches minimum and 5.060 inches maximum
-
Winding Operating Voltage
53.00 ac volts nominal single component 4th secondary
-
Winding Operating Current
20.0 amperes ac maximum single component 2nd secondary
-
Winding Operating Voltage
32.00 ac volts nominal single component 3rd secondary
-
Winding Operating Voltage
14.80 ac volts nominal single component 2nd secondary
-
Mounting Hole Diameter
0.210 inches minimum single group and 0.220 inches maximum single group
-
Mounting Method
bracket single group and unthreaded hole single group
-
Overall Width
4.000 inches maximum
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Winding Function And Quantity
2 primary single component and 5 secondary single component
-
Test Data Document
57057-8892400014 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.240 inches minimum single mounting facility single center group and 2.260 inches maximum single mounting facility single center group
-
Inclosure Type
fully inclosed
-
Special Features
2primary windings; 5secondary windings
-
Winding Tap Location (Non-Core)
err-070
-
Frequency Rating
50.0 hertz minimum single component and 420.0 hertz maximum single component
-
Overall Height
4.500 inches maximum
-
Terminal Type And Quantity
19 solder stud and 3 threaded stud
-
Winding Operating Voltage
13.40 ac volts nominal single component 1st secondary and 8.40 ac volts nominal single component 1st secondary and 16.80 ac volts nominal single component 1st secondary
-
Mounting Facility Quantity
4 single group
-
Winding Operating Current
2.2 amperes ac maximum single component 3rd secondary
-
Winding Operating Current
2.4 amperes ac minimum single component 1st secondary and 3.1 amperes ac maximum single component 1st secondary
-
Unpackaged Unit Weight (Non-Core)
3.8 kilograms
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
114.00 ac volts nominal single component all primary
-
Winding Operating Current
1.6 amperes ac maximum single component 4th secondary
-
Reliability Indicator
not established
-
Maximum Operating Temp
85.0 deg celsius
-
Center To Center Distance Between Mounting Facilities Parallel To Length
4.240 inches minimum single mounting facility single center group and 4.260 inches maximum single mounting facility single center group