SAE186

Coils and Transformers

REACTOR

SAE186

5950-00-006-7160

5950 - Coils and Transformers

United Transformer Corp

REACTOR

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    4 wire lead

  • Rating Method

    electrical single component all winding

  • Winding Operating Current

    8.0 milliamperes maximum of standard range b and better drop siding single component all winding

  • Inductance Rating

    20.00 millihenries nominal single component all winding

  • Dc Resistance Rating In Ohms

    6.000 single component all winding

  • Body Outside Diameter

    0.350 inches maximum

  • Inclosure Type

    fully inclosed

  • Winding Quantity

    2 single component

  • Reliability Indicator

    not established

  • Body Length

    0.410 inches maximum

  • Mounting Method

    terminal single group

  • Frequency Rating

    1.0 kilohertz nominal single component

  • Inductance Type

    fixed

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.