B483AJ41
Filters and Networks
FILTER,BAND PASS
B483AJ41
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.840 inches minimum and 0.860 inches maximum
-
Body Material
metal
-
Frequency Band Width Per Function
487.75 kilohertz 2nd band pass and 487.80 kilohertz 2nd band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Functional Terminal Type And Quantity
4 pin output 2nd function
-
Body Length
1.510 inches maximum
-
Operating Temp Range
-20.0/+71.0 deg celsius
-
Reference Frequency Per Function
487.475 single radio interference pulses per second
-
Overall Height
0.695 inches nominal
-
Unpackaged Unit Weight
42.000 grams
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Body Width
1.120 inches maximum
-
Functional Terminal Type And Quantity
2 pin ground 3rd function
-
Source Impedance Rating Per Function
100.0 ohms 1st band pass
-
Frequency Band Width Per Function
487.45 kilohertz 1st band pass and 487.50 kilohertz 1st band pass
-
Load Impedance Per Function
168.0 kilohms 1st band pass
-
Reference Frequency Per Function
487.775 single radio interference two phase to two phase
-
Load Impedance Per Function
168.0 kilohms 2nd band pass
-
Specified Frequencies Of Discrimination Per Function
487.75 kilohertz 2nd band pass and 487.80 kilohertz 2nd band pass and 486.975 kilohertz 2nd band pass and 488.575 kilohertz 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Specified Frequencies Of Discrimination Per Function
487.45 kilohertz 1st band pass and 487.50 kilohertz 1st band pass and 486.675 kilohertz 1st band pass and 488.275 kilohertz 1st band pass
-
Source Impedance Rating Per Function
100.0 ohms 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass and 1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass
-
Inclosure Type
encased
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.235 inches minimum and 1.245 inches maximum
-
Functional Terminal Type And Quantity
1 pin input 1st function
-
Mounting Facility Type And Quantity
7 terminal
-
Body Height
0.595 inches maximum
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum 1st band pass and 1.5 maximum 1st band pass and 1.5 maximum 1st band pass and 30.0 minimum 1st band pass
-
Vibration Resistance Range In Hertz
+10.0/+2000.0