BFN04-13

Filters and Networks

FILTER,BAND PASS

BFN04-13

5915-00-007-7132

5915 - Filters and Networks

Bliley Electric Co.

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Body Width

    1.120 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.300 inches nominal

  • Functional Terminal Type And Quantity

    2 pin ground 3rd function

  • Source Impedance Rating Per Function

    100.0 ohms 1st band pass

  • Specified Frequencies Of Discrimination Per Function

    479.40 kilohertz 2nd band pass and 478.375 kilohertz 2nd band pass and 479.35 kilohertz 2nd band pass and 480.175 kilohertz 2nd band pass

  • Reference Frequency Per Function

    479.075 single radio interference pulses per second

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

  • Source Impedance Rating Per Function

    100.0 ohms 2nd band pass

  • Inclosure Type

    encased

  • Reference Frequency Per Function

    479.375 single radio interference two phase to two phase

  • Functional Terminal Type And Quantity

    1 pin input 1st function

  • Body Height

    0.595 inches maximum

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 minimum 1st band pass and 1.5 maximum 1st band pass and 1.5 maximum 1st band pass and 30.0 minimum 1st band pass

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Body Material

    metal

  • Frequency Band Width Per Function

    479.05 kilohertz 1st band pass and 479.10 kilohertz 1st band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Specified Frequencies Of Discrimination Per Function

    479.05 kilohertz 1st band pass and 479.10 kilohertz 1st band pass and 478.275 kilohertz 1st band pass and 479.875 kilohertz 1st band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.200 inches nominal

  • Load Impedance Per Function

    160.0 ohms 1st band pass

  • Frequency Band Width Per Function

    479.35 kilohertz 2nd band pass and 479.40 kilohertz 2nd band pass

  • Functional Terminal Type And Quantity

    4 pin output 2nd function

  • Body Length

    1.510 inches maximum

  • Operating Temp Range

    -20.0/+71.0 deg celsius

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 minimum 2nd band pass and 1.5 maximum 2nd band pass and 1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass

  • Load Impedance Per Function

    160.0 ohms 2nd band pass

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Overall Height

    0.695 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.188 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...