F13212-3
Filters and Networks
FILTER,BAND PASS
F13212-3
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
1.510 inches maximum
-
Operating Temp Range
-20.0/+71.0 deg celsius
-
Load Impedance Per Function
160.0 ohms 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass and 1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass
-
Inclosure Type
encased
-
Functional Terminal Type And Quantity
1 pin input 1st function
-
Body Height
0.595 inches maximum
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum 1st band pass and 1.5 maximum 1st band pass and 1.5 maximum 1st band pass and 30.0 minimum 1st band pass
-
Reference Frequency Per Function
476.075 single radio interference pulses per second
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Body Material
metal
-
Specified Frequencies Of Discrimination Per Function
476.40 kilohertz 2nd band pass and 475.575 kilohertz 2nd band pass and 476.35 kilohertz 2nd band pass and 477.175 kilohertz 2nd band pass
-
Style Designator
rectangular terminal/terminals on one surface
-
Reference Frequency Per Function
476.375 single radio interference two phase to two phase
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.200 inches nominal
-
Load Impedance Per Function
160.0 ohms 1st band pass
-
Functional Terminal Type And Quantity
4 pin output 2nd function
-
Frequency Band Width Per Function
476.05 kilohertz 1st band pass and 476.10 kilohertz 1st band pass
-
Specified Frequencies Of Discrimination Per Function
476.05 kilohertz 1st band pass and 475.275 kilohertz 1st band pass and 476.10 kilohertz 1st band pass and 476.875 kilohertz 1st band pass
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Frequency Band Width Per Function
476.35 kilohertz 2nd band pass and 476.40 kilohertz 2nd band pass
-
Overall Height
0.695 inches nominal
-
Unthreaded Mounting Hole Diameter
0.188 inches nominal
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Body Width
1.120 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.300 inches nominal
-
Functional Terminal Type And Quantity
2 pin ground 3rd function
-
Source Impedance Rating Per Function
100.0 ohms 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Source Impedance Rating Per Function
100.0 ohms 2nd band pass