BFN04-34

Filters and Networks

FILTER,BAND PASS

BFN04-34

5915-00-007-9057

5915 - Filters and Networks

Bliley Electric Co.

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Height

    0.695 inches nominal

  • Unpackaged Unit Weight

    42.000 grams

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Body Width

    1.120 inches maximum

  • Functional Terminal Type And Quantity

    2 pin ground 3rd function

  • Source Impedance Rating Per Function

    100.0 ohms 1st band pass

  • Reference Frequency Per Function

    485.225 single radio interference pulses per second

  • Frequency Band Width Per Function

    485.20 kilohertz 1st band pass and 485.25 kilohertz 1st band pass

  • Load Impedance Per Function

    168.0 kilohms 1st band pass

  • Reference Frequency Per Function

    485.525 single radio interference two phase to two phase

  • Frequency Band Width Per Function

    485.50 kilohertz 2nd band pass and 485.55 kilohertz 2nd band pass

  • Load Impedance Per Function

    168.0 kilohms 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

  • Source Impedance Rating Per Function

    100.0 ohms 2nd band pass

  • Functional Terminal Type And Quantity

    1 pin input 1st function

  • Mounting Facility Type And Quantity

    7 terminal

  • Body Height

    0.595 inches maximum

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.840 inches minimum and 0.860 inches maximum

  • Body Material

    metal

  • Style Designator

    rectangular terminal/terminals on one surface

  • Functional Terminal Type And Quantity

    4 pin output 2nd function

  • Body Length

    1.510 inches maximum

  • Operating Temp Range

    -20.0/+71.0 deg celsius

  • Specified Frequencies Of Discrimination Per Function

    485.25 kilohertz 1st band pass and 484.425 kilohertz 1st band pass and 485.20 kilohertz 1st band pass and 486.025 kilohertz 1st band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    30.0 minimum 2nd band pass and 1.5 maximum 2nd band pass and 1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.5 maximum 1st band pass and 30.0 minimum 1st band pass and 1.5 maximum 1st band pass and 30.0 minimum 1st band pass

  • Inclosure Type

    encased

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.235 inches minimum and 1.245 inches maximum

  • Specified Frequencies Of Discrimination Per Function

    484.725 kilohertz 2nd band pass and 485.55 kilohertz 2nd band pass and 485.50 kilohertz 2nd band pass and 486.325 kilohertz 2nd band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...