Technical Characteristics

  • Reference Frequency Per Function

    485.675 single radio interference pulses per second

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

  • Frequency Band Width Per Function

    485.65 kilohertz 1st band pass and 485.70 kilohertz 1st band pass

  • Source Impedance Rating Per Function

    100.0 ohms 2nd band pass

  • Reference Frequency Per Function

    485.975 single radio interference two phase to two phase

  • Frequency Band Width Per Function

    485.95 kilohertz 2nd band pass and 486.00 kilohertz 2nd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass and 1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass

  • Inclosure Type

    encased

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.235 inches minimum and 1.245 inches maximum

  • Functional Terminal Type And Quantity

    1 pin input 1st function

  • Mounting Facility Type And Quantity

    7 terminal

  • Specified Frequencies Of Discrimination Per Function

    485.65 kilohertz 1st band pass and 484.875 kilohertz 1st band pass and 485.70 kilohertz 1st band pass and 486.475 kilohertz 1st band pass

  • Body Height

    0.595 inches maximum

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.840 inches minimum and 0.860 inches maximum

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.5 maximum 1st band pass and 1.5 maximum 1st band pass and 30.0 minimum 1st band pass and 30.0 minimum 1st band pass

  • Body Material

    metal

  • Specified Frequencies Of Discrimination Per Function

    486.00 kilohertz 2nd band pass and 485.95 kilohertz 2nd band pass and 485.175 kilohertz 2nd band pass and 486.775 kilohertz 2nd band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Functional Terminal Type And Quantity

    4 pin output 2nd function

  • Body Length

    1.510 inches maximum

  • Operating Temp Range

    -20.0/+71.0 deg celsius

  • Overall Height

    0.695 inches nominal

  • Unpackaged Unit Weight

    42.000 grams

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Body Width

    1.120 inches maximum

  • Functional Terminal Type And Quantity

    2 pin ground 3rd function

  • Source Impedance Rating Per Function

    100.0 ohms 1st band pass

  • Load Impedance Per Function

    168.0 kilohms 1st band pass

  • Load Impedance Per Function

    168.0 kilohms 2nd band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...