865089-10
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
865089-10
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Current Rating Per Function In Amps
10.0 3rd radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
-
Operating Current Rating Per Function In Amps
10.0 4th radio interference
-
Body Width
6.000 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Overall Length
13.380 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
5.562 inches nominal
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Vibration Resistance Range In Hertz
+10.0/+500.0
-
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at sea level
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
12.875 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Operating Current Rating Per Function In Amps
10.0 1st radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function
-
Maximum Voltage Drop Per Function
575.0 millivolts ac 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
-
Inclosure Type
hermetically sealed
-
Body Length
8.500 inches nominal
-
Maximum Voltage Drop Per Function
140.0 millivolts dc 4th radio interference
-
Maximum Voltage Drop Per Function
575.0 millivolts ac 2nd radio interference
-
Maximum Voltage Drop Per Function
575.0 millivolts ac 3rd radio interference
-
Distance Between Mounting Surface And Lower End
3.500 inches nominal
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Operating Current Rating Per Function In Amps
10.0 2nd radio interference
-
Overall Height
4.250 inches nominal
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Unthreaded Mounting Hole Diameter
0.196 inches nominal
-
Body Height
3.000 inches maximum
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Functional Terminal Type And Quantity
1 connector, receptacle output and 4 turret input and 2 turret ground
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Operating Voltage Rating And Type Per Function
28.0 volts dc 4th radio interference 4th function