930020-24
Filters and Networks
FILTER,BAND PASS
930020-24
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Temp Range
-20.0/+71.0 deg celsius
-
Body Length
1.510 inches maximum
-
Functional Terminal Type And Quantity
4 pin output 2nd function
-
Reference Frequency Per Function
482.525 single radio interference two phase to two phase
-
Style Designator
rectangular terminal/terminals on one surface
-
Specified Frequencies Of Discrimination Per Function
482.20 kilohertz 1st band pass and 481.425 kilohertz 1st band pass and 482.25 kilohertz 1st band pass and 483.025 kilohertz 1st band pass
-
Body Material
metal
-
Frequency Band Width Per Function
482.50 kilohertz 2nd band pass and 482.55 kilohertz 2nd band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.840 inches minimum and 0.860 inches maximum
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Frequency Band Width Per Function
482.20 kilohertz 1st band pass and 482.25 kilohertz 1st band pass
-
Body Height
0.595 inches maximum
-
Mounting Facility Type And Quantity
7 terminal
-
Reference Frequency Per Function
482.225 single radio interference pulses per second
-
Functional Terminal Type And Quantity
1 pin input 1st function
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.235 inches minimum and 1.245 inches maximum
-
Inclosure Type
encased
-
Discrimination At Specified Frequencies Per Function In Decibels
1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass and 1.5 maximum 2nd band pass and 30.0 minimum 2nd band pass
-
Source Impedance Rating Per Function
100.0 ohms 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band pass
-
Load Impedance Per Function
168.0 kilohms 2nd band pass
-
Load Impedance Per Function
168.0 kilohms 1st band pass
-
Source Impedance Rating Per Function
100.0 ohms 1st band pass
-
Functional Terminal Type And Quantity
2 pin ground 3rd function
-
Body Width
1.120 inches maximum
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band pass
-
Specified Frequencies Of Discrimination Per Function
482.50 kilohertz 2nd band pass and 481.725 kilohertz 2nd band pass and 482.55 kilohertz 2nd band pass and 483.325 kilohertz 2nd band pass
-
Unpackaged Unit Weight
42.000 grams
-
Overall Height
0.695 inches nominal
-
Discrimination At Specified Frequencies Per Function In Decibels
1.5 maximum 1st band pass and 30.0 minimum 1st band pass and 1.5 maximum 1st band pass and 30.0 minimum 1st band pass