G146-501-001

Coils and Transformers

TRANSFORMER,AUDIO FREQUENCY

G146-501-001

5950-00-011-8268

5950 - Coils and Transformers

Kearfott Corporation

TRANSFORMER,AUDIO FREQUENCY

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Winding Operating Current

    5.5 milliamperes maximum of standard range b and better drop siding single component single primary

  • Impedance Rating In Ohms

    600.0 nominal single component single secondary

  • Maximum Transformer Power Rating

    500.0 milliwatts single component

  • Body Outside Diameter

    0.350 inches maximum

  • Winding Function And Quantity

    1 primary single component and 1 secondary single component

  • Terminal Type And Quantity

    6 wire lead

  • Frequency Response Tolerance In Decibels (Non-Core)

    -3.0/+3.0 single component

  • Impedance Rating In Ohms

    500.0 nominal single component single primary

  • Reliability Indicator

    not established

  • Body Length

    0.410 inches maximum

  • Mounting Method

    terminal single group

  • Inclosure Type

    hermetically sealed

  • Winding Tap Location (Non-Core)

    center tap single component single primary

  • Frequency Rating

    400.0 hertz minimum single component and 100.0 kilohertz maximum single component

  • Winding Tap Location (Non-Core)

    center tap single component single secondary

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.