2558160-1
Filters and Networks
FILTER,BAND PASS
2558160-1
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Style Designator
rectangular terminal/terminals on one surface
-
Principal Circuitry Type Per Function
crystal 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 2nd band pass and 20.0 minimum 2nd band pass and 3.0 maximum 2nd band pass and 20.0 minimum 2nd band pass
-
Source Impedance Rating Per Function
2.2 kilohms 1st band pass
-
Source Impedance Rating Per Function
2.2 kilohms 2nd band pass
-
Maximum Dielectric Withstanding Ac Rms Voltage
50.0 volts at sea level
-
Mounting Facility Type And Quantity
2 threaded stud
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.112 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.600 inches nominal
-
Reference Frequency Per Function
469.655 single radio interference pulses per second
-
Specified Frequencies Of Discrimination Per Function
469.68 kilohertz 2nd band pass and 469.405 kilohertz 2nd band pass and 469.63 kilohertz 2nd band pass and 469.905 kilohertz 2nd band pass
-
Body Length
2.000 inches maximum
-
Body Height
1.000 inches maximum
-
Inclosure Type
hermetically sealed
-
Load Impedance Per Function
2.2 kilohms 1st band pass
-
Reference Frequency Per Function
469.655 single radio interference two phase to two phase
-
Functional Terminal Type And Quantity
2 pin output 2nd function
-
Body Width
1.000 inches maximum
-
Load Impedance Per Function
2.2 kilohms 2nd band pass
-
Functional Terminal Type And Quantity
2 pin input 1st function
-
Frequency Band Width Per Function
469.63 kilohertz 1st band pass and 469.68 kilohertz 1st band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 1st band pass and 20.0 minimum 1st band pass and 3.0 maximum 1st band pass and 20.0 minimum 1st band pass
-
Overall Height
1.420 inches nominal
-
Functional Terminal Type And Quantity
3 pin ground 3rd function
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.5 1st band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.600 inches nominal
-
Insertion Loss At Reference Frequency Per Function In Decibels
3.5 2nd band pass
-
Operating Temp Range
-0.0/+60.0 deg celsius
-
Frequency Band Width Per Function
469.63 kilohertz 2nd band pass and 469.68 kilohertz 2nd band pass
-
Principal Circuitry Type Per Function
crystal 1st band pass
-
Specified Frequencies Of Discrimination Per Function
469.68 kilohertz 1st band pass and 469.405 kilohertz 1st band pass and 469.63 kilohertz 1st band pass and 469.905 kilohertz 1st band pass
-
Body Material
metal