P16AA4

Switches

SWITCH,PRESSURE

P16AA4

5930-00-013-9820

5930 - Switches

Johnson Controls Inc

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Method

    inlet connection

  • Contact Voltage Rating In Volts

    120.0 ac at sea level second voltage

  • Style Designator

    rectangular

  • Contact Stimulus Rating

    75.00 deactuation point nominal pounds per square inch and 80.00 actuation point nominal pounds per square inch and 5.00 differential point nominal pounds per square inch

  • Thread Quantity Per Inch

    18 single pressure connection

  • Contact Load Current Rating

    3.0 amperes resistive load fourth voltage

  • Features Provided

    electrical access port

  • Contact Voltage Rating In Volts

    230.0 dc at sea level third voltage

  • Pressure Switch Type

    gage

  • Contact Load Current Rating

    24.0 amperes resistive load first voltage

  • Nominal Thread Size

    0.250 inches single pressure connection

  • Contact Adjustability

    deactuation point not adjustable and actuation point not adjustable

  • Pressure Connector Type

    plain, threaded internal single connection

  • Contact Action Stimulus

    increase

  • Thread Series Designator

    npt single pressure connection

  • Precious Material

    silver

  • Contact Voltage Rating In Volts

    115.0 dc at sea level fourth voltage

  • Contact Load Current Rating

    24.0 amperes resistive load second voltage

  • Overall Length

    3.938 inches nominal

  • Terminal Type

    tab w/screw

  • Inside Diameter

    0.250 inches nominal single connection

  • Media For Which Designed

    gas

  • Overall Width

    3.734 inches nominal

  • Nonpile-Up Contact Arrangement

    2 pole, single throw, normally closed, momentary action

  • Body Height

    3.734 inches nominal

  • Contact Load Current Rating

    500.0 milliamperes resistive load third voltage

  • Precious Material And Location

    contacts silver

  • Overall Height

    5.046 inches nominal

  • Err Default

    err default

  • Contact Voltage Rating In Volts

    240.0 ac at sea level first voltage

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...