840019-12

Circuit Breakers

CIRCUIT BREAKER

840019-12

5925-00-022-5631

5925 - Circuit Breakers

Bae Systems Information And

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.250 inches nominal

  • Reset Method

    manual

  • Trip Release Ambient Temp Rating

    25.0 deg celsius maximum single location

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 200 pct single location and 1.800 maximum at 200 pct single location

  • Terminal Type And Quantity

    2 screw

  • Mounting Surface To Terminal End Distance

    1.812 inches maximum

  • Body Length

    1.137 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 6000.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Width

    0.687 inches nominal

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    0.704 inches nominal

  • Frequency In Hertz

    400.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 push-pull

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    thermal single location

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac single location and 2.5 amperes dc single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...