10-P-167

Relays and Solenoids

RELAY,ELECTROMAGNETIC

10-P-167

5945-00-027-1359

5945 - Relays and Solenoids

Specific Systems Ltd.

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    2.687 inches nominal single mounting facility

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    2.865 inches nominal single mounting facility

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac resistive load and 5.0 amperes dc resistive load

  • Environmental Protection

    hermetic

  • Auxiliary Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Arc Quenching Method

    air

  • Overall Width

    3.305 inches maximum

  • Overall Height

    2.941 inches maximum

  • Winding Quantity

    1

  • Main Contact Load Current Rating At Maximum Rated Voltage

    50.0 amperes ac resistive load and 50.0 amperes dc resistive load

  • Case Material

    metal

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac inductive load and 5.0 amperes dc inductive load

  • Unthreaded Mounting Hole Diameter

    0.218 inches nominal single mounting facility

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Nonpile-Up Auxiliary Contact Arrangement

    1 pole, single throw, normally closed, double break, momentary action and 1 pole, single throw, normally open, double make, momentary action

  • Cubic Measure

    36.245 cubic inches

  • Main Contact Load Current Rating At Maximum Rated Voltage

    50.0 amperes ac inductive load and 50.0 amperes dc inductive load

  • Terminal Type And Quantity

    12 threaded stud all functions

  • Purpose For Which Designed

    general

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    1.0 amperes ac motor load and 1.0 amperes dc motor load

  • Operating Voltage Rating And Type At Specified Temp

    28.0 volts dc 25 deg celsius single winding

  • Coil Quantity

    1

  • Main Contact Load Current Rating At Maximum Rated Voltage

    50.0 amperes ac motor load and 50.0 amperes dc motor load

  • Specification/Standard Data

    96906-ms27222 government standard

  • Winding Dc Resistance Rating

    51.0 ohms nominal single winding

  • Time Delay

    0.05 seconds maximum fixed release time

  • Time Delay

    0.025 seconds maximum fixed operate time

  • Duty Type

    continuous

  • Nonpile-Up Main Contact Arrangement

    3 pole, single throw, normally open, double make, momentary action

  • ~1

    data on certain environmental and performance

  • Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    4 unthreaded hole single mounting facility

  • Overall Length

    3.734 inches maximum

  • Mounting Facility Pattern

    rectangular single mounting facility

  • Storage Type

    general purpose warehouse

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...