F10884
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
F10884
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
6.620 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
4.250 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Operating Current Rating Per Function In Amps
30.0 2nd radio interference
-
Inclosure Type
encased
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Operating Current Rating Per Function In Amps
30.0 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Operating Voltage Rating And Type Per Function
200.0 volts ac 1st radio interference 1st function
-
Unthreaded Mounting Hole Diameter
0.235 inches nominal
-
Body Material
metal
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Functional Terminal Type And Quantity
6 tab, solder lug input 1st function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Operating Temp Range
-65.0/+160.0 deg fahrenheit
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
-
Body Length
7.620 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Vibration Resistance Range In Hertz
+5.0/+500.0
-
Operating Voltage Rating And Type Per Function
200.0 volts ac 2nd radio interference 2nd function
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Operating Voltage Rating And Type Per Function
28.0 volts dc 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function
28.0 volts dc 5th radio interference 5th function
-
Overall Length
8.250 inches maximum
-
Operating Voltage Rating And Type Per Function
28.0 volts dc 6th radio interference 6th function
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Operating Current Rating Per Function In Amps
30.0 1st radio interference
-
Functional Terminal Type And Quantity
6 tab, solder lug output 2nd function
-
Operating Voltage Rating And Type Per Function
200.0 volts ac 3rd radio interference 3rd function
-
Overall Height
3.940 inches nominal
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Operating Current Rating Per Function In Amps
0.5 4th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
7.500 inches nominal
-
Operating Current Rating Per Function In Amps
0.5 5th radio interference
-
Operating Current Rating Per Function In Amps
0.5 6th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference